Medicom MTD logo Medical equipment for electrodiagnosis, rehabilitation and research
 
PRODUCTS


Electroencephalograph-recorder
"ENCEPHALAN-EEGR-19/26"
 

Six in one !

Telemetry EGG-Studies

Neuromonitoring in reanimation and intensive care units

Ambulatory EEG-monitoring

 

EEG-videomonitoring
(Stationary set)

EEG-videomonitoring
(Portable set)

Polysomnographic studies


 
 

ENCEPHALAN-131-03 Series
of Electroencephalograph-Analysers

ENCEPHALAN-131-03 Series of Electroencephalograph-Analysers are efficient instruments for quality EEG assessment. ENCEPHALAN-131-03 systems are widely used in Function Diagnosis, Neurophysiology, and Epileptology.

Models with 8, 16, 19 or 24 EEG leads (up to 32 digital channels), 6 Rheoencephalographic (REG) and 2–6 Polygraphic (ECG, EOG, EMG, RESP) channels.

Full set of studies and data analysis tools: Visual Evaluation tools, Functional Tests, EP Analysis, Topographic Mapping, 3D Source Localization, Study Report Generation, etc.

RF Patent Protected
Combined EEG and REG Analysis.
Proprietory Software for Any Need: "Basic", "Optimal", "Expert", and "Elite" versions.

Details >


ENCEPHALAN-EK EEG Cap & Electrode Kit  
Real Alternative to Traditional EEG Pickup, ENCEPHALAN-EK proprietory EEG Cap & Electrode Kit with a set of Elastic EEG Caps and Detachable AgCl Electrode Systems ensures patient comfort and high-quality EEG recording for professional EEG data assessment.

 ENCEPHALAN-EK Cap-Electrode Kit is compatible with ENCEPHALAN devices and offers accurate EEG acquisition according to standard 10-20 International System.

Main difference and advantage of ENCEPHALAN-EK Cap-Electrode Kit, compared to its foreign analogues, lies in Long-Term Usage of a more expensive Detachable Electrode Kit while a set of Cheaper EEG caps can be easily replaced as they become inoperative due to frequent washing and disinfection.

Details >


 
  RHEAN-POLY
Rheograph-Polyanalyser

Full Set of Rheographic Studies including rheoencephalographic (REG), rheovasographic (RVG), tetrapolar chest rheography (TCR) with bipolar or tetrapolar recording of any blood circulation area.

4 Rheograph-Polyanalyser Models come with 2–6 rheographic inputs and 2–6 polygraphic (ECG, EEG, PPG, etc.) channels for efficient System Blood Flow Assessment.

A Unique Feature!
Real-Time System Hemodynamics Analysis with beat-to-beat index variability of up to 50 parameters is an innovative, powerful instrument for Comprehensive Blood Flow Study.

A Unique Feature!
Combined EEG Analysis with Central, Cerebral and Peripheral Blood Flow Study to reveal correlations between Brain Electric Activity and Cerebral Blood Flow.

Details >


Certificate of Compliance

A Unique Feature!
Acoustic Sensory Chair for special biofeedback procedures or mental relaxation sessions.

For more information, visit www.reacor.ru
REHACOR
Rehabilitative Psychophysiological Biofeedback System
 
Efficient Biofeedback Procedures based on a variety of physiological indices: EEG, HR, GSR, EMG, Blood Flow, Respiration, etc.

Multi-Target Biofeedback Sessions included in Biofeedback Library allow to implement virtually all known biofeedback approaches.

Biofeedback Training to acquire new skills for stress resistance and enchance the adaptive capacities of the body.

Behavioral State Correction in hyperactivity or attention deficit syndrome in children.
A Unique Feature!
Expandable Biofeedback Library with Biofeedback Editor to create new or edit existing biofeedback procedures.

A Unique Feature!
Multiparametric Patient Monitoring during a biofeedback training or rehabilitative procedure.

Non-medicamentous Rehabilitation of impaired body functions, improving the nervous control in abnormal and stress conditions, phobias, abnormal dependences; correction of psycho-emotional state in persons engaged in emotionally or mentally strenious or highly responsible jobs.

Stabilo-Platform for rehabilitation of posture and movement disorders.


Can be used independenly or as part of Rehacor biofeedback system



For detailed information, visit web-site: www.reacor.ru
 
  Acoustic Sensory Chair
for mental relaxation and specialized biofeedback procedures.
 Rehacor biofeedback system may incorporate Acoustic Sensory Chair (ASC) with 16 active independent sources of acoustic vibrations, a library of relaxing and activating biofeedback scenarious, and a scenario editor to pre-program ASC Chair acoustic field's spatiotemporal features based on any audio materials on your computer (CD-disks, MPEG-files, etc.)
 ASC Chair provides a means to perform, according to pre-defined programs, effective psychological audio and vibrotactile activation/relaxation procedures and biofeedback training procedures based on various physiological variables monitored by the psychophysiological rehabilitation system. In the latter case, ASC Chair serves as a spatially distributed acoustic biofeedback transducer.
ASC Chair can be used efficiently for different types of breathing exercises, serving as phase duration/rhythm driver of the breathing cycle.


  Rehabilitative biofeedback procedures using efficient auditory and visual biofeedback tools of REACOR system help to reduce the period of equilibrium rehabilitation in neurological (especially post-stroke), neurosurgical (after spinal or brain surgery), traumatic, surgical, and therapeutic (after prolonged bed rest regimen) patients.)
STABILAN-01 Stabilographic Platform
Option for REHACOR rehabilitative biofeedback system
 
 Biofeedback gaming and stabilographic sessions help to improve the body balance control in athletes, ballet-dancers, etc. and to restore workability of people, which spend a lot of time in a static position at work.

 Stabilographic platform allows to record, process and analyse trajectories of a person's center of pressure (PC) exerted on the support plane. This makes Stabilan-01 platform an effiicient instrument for diagnosis and assessment of a patient's psychophysiologic status.

 Employing the stabilographic platform in the visual and auditory modality biofeedback procedures provided by REHACOR system allows to efficiently apply biofeedback approach in rehabilitation of locomotor and coordination disorders, cerebrovascular abnormalities in post-stroke period and as well in training patients to maintain upright posture.


 
  PSYCHOPHYSIOLOG
Psychophysiological Testing System
 Set of Psychophysiological Tests (up to 16 tests) including HRV, Full MMPI Quiz, Mini-Mult Quiz, Anxiety Test, Leonard's Quiz, Complex and Simple Oculomotor Response Tasks, etc.

A Unique Feature!
Portable PSYCHOPHYSIOLOG device for mobile applications with memory of up to 500 full studies to be later transferred to doctor computer.
Preshift Examination of Function State and Workability of Personnel. Class groups of up to 30 persons for simultaneous psychophysiological testing.

  Efficient Mix of Conventional Psychologic Tests with Advanced Signal Recording and Information Processing Technologies.


ANCAR
12-Lead ElectroCardiograph-Analyser
 
  Full Cycle of ECG Study - from patient card creation to qualified medical report delivery.

  22-Bit ADCs allow high-quality, accurate ECG recording of unlimited duration.

  Index Variability Monitoring of all quantitative ECG parameters (HR, QT and PQ intervals, ST elevation, etc.) simulataneously with raw ECG signals for efficient assessment of their trends and correlations.

  QT Variance Analysis for efficient diagnosis of sudden cardiac death.

  ECG Study Report Generation based on selected cardiac indices at rest and during functional tests.

  Autonomic Nervous System Test based on Heart Rate Variability.

  ECG Stress-Tests. Veloergometry

Details >


RF Patents NN 2076625, 2102004

 
  NEUROMYAN
4-Lead Neuromyograph-Analyser
  Neuromyograph-Analyser for EMG and Evoked Potential Studies.

  Basic Version – for wide clinical practice to assess Peripheral Nerve and Muscle Conditions and study the Hearing and Vision Systems.

  Professional Version – for Fine Differential Diagnosis of Central and Peripheral Nervous System Disorders.

  Pattern-Shift Visual EP Studies (checkerboard VEPs, etc.)

  Transcranial Magnetic Stimulation

Details >