Electroencephalographs-recorders computerized portable "Encephalan-EEGR-19/26" (main modification)
|
 |
Electroencephalographs-recorders computerized portable "Encephalan-EEGR-19/26" ("Mini" modification)
|
 |
|
Cerebral Function Monitor "Encephalan-CFM"
|
 |
|
Psychophysiological telemetric system "Rehacor-T"
|
 |
|
Electroencephalograph-analyzer EEGA-21/26 "Encephalan-131-03"
|
 |
|
Neuromyoanalyzer "Neuromyan"
|
 |
|
 |
Electroencephalograph-recorder "ENCEPHALAN-EEGR-19/26" (main modification) Illustrated product list
| Ref. no. |
Component |
Use |
| A_2700 |
Patient EEG Transceiver-recorder "ABP-26" |
 |
Providing registration of EEG, ECG, EMG, EOG and other physiological signals. |
| A_0294 |
Wireless PC Àdapter IB-4 |
 |
Connected to PC via USB. Ensures connection of all wireless devices
with PC via Bluetooth. |
| A_4179 |
Calibrator |
 |
Is connected to the ABP input instead of the electrode system in order to check working efficiency of ABP and calibration of the EEG, EOG, EMG and RR channels. Ensures the packet of harmonic motion and step voltage. Power from ABP. |
| A_2894 |
Battery Charger |
 |
Is connected to the ABP input instead of the electrode system in order to check working efficiency of ABP and calibration of the EEG, EOG, EMG and RR channels. Ensures the packet of harmonic motion and step voltage. Power from ABP. |
| A_4006 |
Patient EEG Transceiver-recorder "ABP-10" |
 |
Is intended for recording EEG, ECG, EMG, EOG and other physiological signals. |
| A_4003 |
Calibrator |
 |
Is connected to the ABP and intended to calibrate EEG channels and to check EEG Recorder function. |
| Sets of Electrodes and accessories |
 |
Contains 5 sizes of elastic fixing caps and covers for them, brushes for electrode cleaning, disposable ECG, EMG, EOG electrodes - 50 pcs., electrode gel – 1 bottle
|
| A_2493-21 |
Set of Electrodes and Accessories "baby" (electrode system ES-EEG-13-3B, sizes from 34 to 45) |
 |
| A_2493-22 |
Set of Electrodes and Accessories "children" (electrode system ES-EEG-19-3C, sizes from 45 to 55) |
 |
| A_2493-23 |
Set of Electrodes and Accessories "adult" (electrode system ES-EEG -19-3A, sizes from 55 to 66) |
| À_2493-31 |
Set of Electrodes and accessories "baby" (electrode system ES-EEG-11-3B, sizes from 34 to 45) |
 |
| À_2493-32 |
Set of Electrodes and accessories "children" (electrode system ES-EEG -11-3C, sizes from 45 to 55) |
| À_2493-33 |
Set of Electrodes and accessories "adult" (electrode system ES-EEG -11-3A, sizes from 55 to 66) |
| À_2801 |
Connector "EEG-20" |
 |
Is connected to the APB input instead of the electrode system and up to 22 electrodes with tooth-proof connection are connected to it. |
| À_6044 |
Electrodes Set and Accessories for Connector EEG-20 |
 |
For routine EEG: set of cup EEG electrodes KEEG-8/21-01 (25 electrodes and 4 ear clips), EEG caps (silicon tubes) of 3 sizes, universal cables (5 pcs.) for ECG, EOG, EMG; disposable electrodes ECG, EMG, EOG (50 pcs.), electrode gel (1 bottle) |
| A_1854 |
Electrode Gel |
 |
For EEG, ECG and EMG |
| À_2229 |
Set of ECG electrodes (3 clips) |
 |
For ECG recording |
| A_5330 |
Set of Typical Cup EEG Electrodes for EEG-20 connector with touchproof connectors |
 |
For long term EEG and PSG recording – 30 electrodes (2 sets with 15 electrodes), universal cables (5 pcs.) for ECG, EOG, EMG; disposable electrodes ECG, EMG, EOG (50 pcs.). Electrode Cream EC-2 (1 tube). |
| A_6532 |
Electrode Cream EC-2 (tube) |
 |
For EEG cup electrodes |
| A_2669 |
Ten20 Conductive Paste (jar) |
 |
For EEG cup electrodes |
| A_5440 |
Mains Supply Adapter for APB-26 |
 |
Adapter can be inserted into battery compartment instead of
batteries. Adapter is meant for ABP mains supply. |
| A_5448 |
USB Power Supply Adapter |
 |
Adapter can be inserted into battery compartment instead of
batteries. Adapter is meant for ABP power supply from PC USB port. |
| A_5527 |
Desktop Mount for APB-26 |
 |
Is meant for fixing the ABP to the workplace. |
| A_2800 |
Floor Stand for APB-26 |
 |
For fixing the ABP to the workplace. |
| A_2624 |
Wireless stimulator SFN/FO-04 |
 |
Intended for joint use with EEG-recorder while carrying out
functional tests of phono-, photo- and electrostimulation, also it can
be used for study of long-latency EPs. |
| A_3149 |
Headphones |
 |
Executive unit is connected to stimulator SFN/FO-04. Designed for
reproducing audio stimuli (tones, beeps, clicks). |
A_2940,
A_3072 |
LED Tube FO-06 TD (children),
LED Tube FO-06 TV (adults) |
 |
Connectable to SFN/FÎ-04 photostimulators. FÎ-03 is designed for
photostimulation of the patient with eyes opened, FÎ-06 - for
photostimulation through closed eyelid. |
| A_4008 |
Wireless Electrostimulator |
 |
Designed for somatosensory stimulation. Control over stimulator is
performed from stimulator SFN/FO-04 via Bluetooth. |
| À_6430 |
Floor Stand for wireless photic stimulator |
 |
For fixing the stimulator to the workplace. |
| À_5894 |
Table Support for photic stimulator |
 |
For fixing the stimulator to the workplace. |
| A_1715 |
Voice Event Marker DCM-32M |
 |
Designed for recording voice marks in the process of study. |
| A_2329 |
SW-key |
 |
Allows running software on additional PC for analyzing and viewing
recorded studies data. |
| A_2143 |
Memory Card |
 |
Plugged into ABP. Designed for saving all recorded data and some
event markers. |
| Ref. no. |
Component |
Use |
| — |
EEG-Videomonitoring Kit |
Designed for EEG videomonitoring, includes video cameras, microphone, and means to input videosignal into PC. |
| A_2310-31 |
Mobile Basic (Day) |
 |
One professional daylight video camera – optical Zoom, rotator, quality MPEG4, patient’s microphone, portable stand for camera |
| A_2310-32 |
Mobile Basic (Day-Night) |
 |
One professional day-night video camera – digital Zoom, rotator, quality MPEG4, IR backlight for night mode, patient’s microphone, portable stand for camera |
| A_2310-33 |
Mobile Basic Advanced (Day-Night) |
 |
One professional day-night video camera – optical Zoom, rotator, quality MPEG4, IR backlight for night mode, patient’s microphone, portable stand for camera |
| A_2310-34 |
Stationary Professional (2 cameras) |
|
one professional daylight video camera – optical Zoom, rotator; second video camera with night mode – digital Zoom, rotator, IR lamp for night mode; two-way voice communication between operators room and patient’s ward: two microphones – for a doctor and a patient; two event markers, patients events IR receiver |
| A_2310-35 |
Stationary Professional Advanced (2 professional cameras) |
|
one professional daylight video camera – optical Zoom, rotator; second video camera with night mode – optical Zoom, rotator, IR lamp for night mode; two-way voice communication between operators room and patient’s ward: two microphones – for a doctor and a patient; two event markers, patients events IR receiver |
| A_6433 |
Stationary Video Camera |
|
High resolution video camera with IR floodlight for stationary kits for high quality video recording primarily during night |
| A_2651 |
Events Marker (IR, wireless) |
 |
Allows setting event marks in the studies record directly from patient’s ward. |
| A_4009 |
Patient Button Unit |
 |
Cooperates with ABP with the help of Bluetooth. Is designed for fixation of motor reaction of the patient to stimulus in some cognitive examination programs. |
| A_4178 |
Videostimulus Synchronization Sensor |
 |
Designed for apparatus record of video frame display moment in some cognitive examination programs. Fixed in the corner of the screen and connected to the Patient Button Unit. |
| A_5743 |
Connector "Poly-6" |
 |
Module cooperates with ABP with the help of BlueTooth and adds to the system 6 polygraphic channels. |
| A_4626 |
ABP-BFB electrodes, sensors and accessories Kit – for biofeedback training with "Rehacor" software |
 |
Includes sensors and cables of GSR, skin conductance, PPG – 1 pcs; respiration effort, temperature, EEMG – 2 pcs; ECG cable – 1 pcs.; universal electrode cable for EEG and EMG derivations – 2 pcs., tubular EEG electrodes – 2 pcs; ECG, EMG, EOG disposable electrodes (50 pcs.), electrode gel (1 tube) |
| A_6541 |
Caps Set "Children", 5 sizes from 45 to 55 |
 |
Elastic EEG caps CS-EEG-FBC-C |
| A_6542 |
Caps Set "Adult", 5 sizes from 55 to 66 |
Elastic EEG caps CS-EEG-FBC-A |
| A_6473 |
Stabiloanalyzer (balance platform) |
 |
For additional diagnostics and BFB training by stabylogram (adapter required - item 27.4.1) |
| A_4813 |
Wireless I/O Adapter |
 |
For stabyloanalyzer |
| Ref. no. |
Component |
Use |
| A_2732 |
Wireless Movement Sensor |
|
Module cooperates with ABP-5 with the help of Bluetooth and designed for recording patient’s extremities motor activity. |
| A_4404 |
Wireless Respiration Module |
|
Registers 4 channels of respiratory sensors (item 30.1) synchronously with EEG. Used for respiration disorders detection during PSG studies |
| A_5365 |
Set of Sensors and Accessories for Wireless Respiration Module |
|
Respiration effort sensors, thoracal and abdominal, snore sensor, oral and oral-nasal thermistor airflow sensors, nasal cannula (disposable cannulas should be purchased individually.
The set can be used with POLY-4 module or ABP-10 to record signals via 10 polygraphic channels (POLY-10)
|
| A_4163 |
Wireless Pulseoximeter Module |
 |
Module cooperates with ABP with the help of Bluetooth and designed for record of oxygen degree in blood. |
| A_4085-05 |
Fingertip SpO2 Sensor R-3227 (soft small) |
 |
— |
| A_4085-03 |
Fingertip SpO2 Sensor R-3227 (soft medium) |
 |
— |
| A_4085-04 |
Fingertip SpO2 Sensor R-3227 (soft large) |
 |
— |
| A_4085-06 |
Neonatal Disposable Spo2 Sensor DN-2311-6 (set of 24 pcs.) for neonatal use |
 |
— |
| A_2442 |
Wireless Cardiorespiratory Module |
 |
Module cooperates with ABP with the help of Bluetooth and adds to the system 4 channels for 1 channel respiration parameters record and ECG via 3 derivations. |
| A_4768 |
PG-ECG Connector |
 |
Connected to the Wireless Cardiorespiratory Module. Is designed for connection of cables from the PG-ECG Cable Kit. |
| A_5359 |
POLY-4 Wireless Module
|  |
Module cooperates with ABP with the help of Bluetooth and adds to the system 4 polygraphic channels. |
| A_5228 |
USB Power Supply Adapter |
 |
Adapter can be inserted into battery compartment instead of batteries. Adapter is designed for "Poly-4" power supply from PC USB port. |
| A_5346 |
Mains Supply Adapter |
 |
Adapter can be inserted into battery compartment instead of
batteries. Adapter is designed for "Poly-4" mains supply. |
| A_5364 |
ABP-POLY Electrodes, Sensors and Accessories set |
 |
For monitoring the movement activity in natural behavior and also for Study of Limbs Movements During Sleep. Includes movement sensors (wired) – 2 pcs., cables for 2 EMG derivations), disposable electrodes are required.
The set can be used with Poly-4 module (item 35) or ABP-10 (item 36) in the POLY-10 mode.
|
| A_6436 |
Patient Transceiver-Recorder ABP-10 in the Mode of 10 Universal Polygraphic (POLY-10) Channels |
 |
For "Poly" version of electroencephalograph, as additional device to the main ABP-26 (independent use is not intended). The delivery set contains rechargeable batteries set, charger, calibrator, cover-bag. Electrodes and sensors are delivered according to customer’s needs. Used mainly for scientific research and for multiparametric (telemetric or autonomous) monitoring in sport medicine and psychophysiology.
|
| A_5360 |
USB Power supply adapter for ABP-10 module |
 |
Adapter can be inserted into battery compartment instead of batteries. Adapter is meant for ABP power supply from PC USB port.
|
| A_5447 |
Mains supply adapter for ABP-10 module |
 |
Adapter can be inserted into battery compartment instead of batteries. Adapter is meant for ABP mains supply.
|
| Ref. no. |
Component |
Use |
| A_4772 |
Tetrapolar Rheographic Adapter (RT) |
 |
For evaluation of central hemodynamics rheography and heart pumping ability parameters |
| A_5338 |
Accessories and electrodes set for rheographic adapter RT |
 |
For carrying out of rheographic studies, using RT Rheographic Adapter |
| A_4771 |
Bipolar rheographic adapter (RB) for REG and RVG |
 |
For evaluation of cerebral (REG) and peripheral (RVG) blood circulation, which characterizes pulse blood filling, variable diameter vessels tone and venous drainage state |
| A_5339 |
Accessories and electrodes set for rheographic adapter RB |
 |
For carrying out of rheographic studies, using RB Rheographic Adapter |
| A_2673 |
Respiratory Effort Sensor |
 |
Sensor with respiratory belt to record thoracic and abdominal respiration.
(All electrodes and sensors designed for connection to ABP, RR module, Wireless cardiorespiratory module (PG-ECG), Wireless Module "Poly-4", are supplied with 8-pin connectors.)
|
| A_4406 |
Pressure Airflow Sensor |
 |
Designed for respiration airflow evaluation by means of air pressure registering. |
| A_4007-03 |
Disposable Nasal Cannula (neonatal) |
| A_4007-02 |
Disposable Nasal Cannula (children) |
| A_4007-01 |
Disposable Nasal Cannula (adult) |
| A_5697 |
Oral Airflow Sensor (Thermistor "T-Flow") |
 |
Evaluates parameters of oral respiration (breathing rate and amplitude, duration of in-and exhalation phases) and detects breathing disorders basing on temperature changes of oral airflow. |
| A_2326 |
Oro-Nasal Airflow Sensor (Thermistor "T-Flow") |
 |
Evaluates parameters of nasal respiration (breathing rate and amplitude, duration of in-and exhalation phases) and detects breathing disorders basing on temperature changes of oro-nasal airflow. |
| A_1869 |
Snore Sensor ("Snore") |
 |
Detects and evaluates snoring during sleep quantitatively |
| A_4140 |
Ear PPG Sensor |
 |
Record of the pulse curve to calculate peripheral circulation. |
| A_4141 |
Surface PPG Sensor |
 |
Record of the pulse curve to calculate peripheral circulation. |
| A_4139 |
Temperature Sensor |
 |
Designed for temperature record. |
| A_4142 |
Envelope EMG Sensor (double) |
 |
Record of muscle tone via envelope EMG. |
| A_5731 |
Envelope EMG Sensor (triple) |
 |
Record of muscle tone via envelope EMG. |
| A_4143 |
GSR Sensor |
 |
Galvanic skin response record (relative impedance change). |
| A_5119 |
Skin Conductance Sensor (EDA-ElectroDermal Activity) |
 |
Evaluates vegetative manifestations and emotional stress basing on phase and tonic component measurement |
| A_5118 |
Light sensor |
 |
For evaluation of light conditions in a room during the somnological studying. |
| A_5117 |
Wet Sensor |
 |
Designed for detecting wet caused by urination. |
| A_5361 |
Movement Sensor |
 |
Designed for recording patient’s extremities motor activity. |
| A_2073 |
ECG Cable for Disposable Electrodes |
 |
Designed for connecting the ECG electrodes. |
| A_3817 |
Cable for Disposable N Electrode |
 |
With TouchProof connector for Poly-6 and EEG-20 |
| A_4194 |
Bipolar EÌG Cable |
 |
With 2 snap connector for disposable. |
| A_2741 |
Disposable ECG electrode F26 PG-10S |
 |
N-electrode universal. |
| A_3022 |
Biadhesive Electrode-Fixing Disks F9026F (F20/8, double-sided adhesive washers) |
 |
For firm fixation of mastoidal referent electrodes, snore sensor, wired movement sensor – 500 pcs in a pack |
| Ref. no. |
Component |
| — |
Real Time Work Station with Installed Medicom-MTD Software Suite (Portable Computer) |
 |
| — |
Real Time Work Station with Installed Medicom-MTD Software Suite (Portable Computer) with Additional LCD Monitor 22", Laser Black-And-White Printer A4 format, Equipment Trolley and Videomonitoring kit |
 |
| — |
Real Time Data Analysis and Storage Station with installed Medicom-MTD Software Suite (Stationary Computer) with Additional LCD Monitor 22", Laser Black-And-White Printer A4 format and Equipment Trolley |
 |
| A_4742 |
Bluetooth-GPS module |
 |
For tracking patient's location |
|