Home page Medical equipment for electrodiagnosis, rehabilitation and research
DELIVERY SET

Electroencephalographs-recorders computerized portable "Encephalan-EEGR-19/26"
("Mini" modification)



European Quality Certificate CE 538571 issued by British Standards Institute (BSI) valid till 02/09/2013
Registration Certificate of Federal Supervision Service for Healthcare and Social Development #FSR 2009/05646 issued from 08.09.2009


Electroencephalograph-recorder computerized portable "Encephalan-EEGR-19/26", "Mini" modification, is a multichannel (11 channels with option of increasing up to 26 channels), multifunctional device for study carrying out at various environments – in functional diagnostics room, ambulance car, ICU and reanimation, medical ward, patient’s place (at home, while performing activities, during sleep etc.), in telemetric and autonomous (portable) modes.

Electroencephalograph-recorder can be used for:


  • functional EEG-studies (9 maximal EEG derivations) with topographic mapping of electrical brain activity in telemetric mode with portable or stationary PC;

  • long-term monitoring of electroencephalograms (electrical brain activity) and evoked potentials studying;

  • long-term EEG video monitoring, in a stationary or mobile variants in neurological or epileptological departments of medical institutions or at patient's home;

  • specialized neuromonitoring and / or cerebral function monitoring in intensive care units and reanimation;

  • long-term (more than 48 hours saving data onto the memory card) autonomous studies (Holter type) in patient friendly environment with patient’s freedom of movement;

  • somnological (PSG) studies, that can be made in telemetric mode with optional video monitoring as well as in autonomous (Holter type) modes;

  • multiparametric telemetric or autonomous monitoring (free movements of a patient, a sportsmen, a test person) with an option of additional psychophysiological and neurophysiological testing and state training in sport, industrial medicine and psychophysiology, and for scientific researches.

Electroencephalograph-recorder "Encephalan-EEGR-19/26" can be delivered in 4 versions:


  • "Encephalan-EEGR-19/26" AT-Mini – for routine telemetric EEG studies with functional tests (phono-photostimulation) or for long-term telemetric (with backup data copying) or autonomous (Holter type) monitoring of EEG by 9 derivations and other signals (with additional wireless recording devices). Version can be delivered without function of data recording on a memory card. This function can be added later, if required.

  • "Encephalan-EEGR-19/26" AT-Mini-Video – for long-term monitoring of EEG by 9 derivations and other signals with synchronized videomonitoring.

  • "Encephalan-EEGR-19/26" AT-Somno – for somnological studies using 2 or 6 EEG derivations, cardiorespiratory indices, oxygen saturation and other channels, selected by customer.

  • "Encephalan-EEGR-19/26" AT-Somno-Video – for somnological studies using 2 or 6 EEG derivations, cardiorespiratory indices, oxygen saturation or other channels, selected by customer with synchronized videomonitoring.



This data is of informative character. To form the specific set of equipment for delivery address the commercial department.

Illustrated product list

Each version can be completed with additional software for extending functional capabilities of electroencephalograph.
Versions are formed according to the table below by agreement with the customer:

Devices and accessories for completing of main delivery set of Electroencephalograph-recorder "Encephalan-EEGR-19/26" "Mini" modification, version AT

Item # Ref. no. Description
1. À_6035 Basic set of Electroencephalograph-Recorder "Encephalan-EEGR-19/26" Modification "Mini" (for telemetric EEG studies) version AT-Mini (without function of data recording on a memory card) and also for versions PSG, Video, Poly supply, with possibility of functioning in telemetric mode only.
    Basic set for À_6035 includes:
    • Patient transceiver-recorder (ABP-10): 9 EEG, 1 ECG, integrated body position sensor, ABP-10 can be used as a recorder with 10 custom polygraphical channels (also for PSG with 6 or 2 EEG channels); integrated telemetric interface (Bluetooth®) for connecting with PC and additional wireless devices;
    • Rechargeable batteries set – 2 pcs., charger, calibrator, cover bag, operation documentation;
    • Wireless PC Adapter IB-4 (USB–Bluetooth);
    • Software for telemetric EEG studies "Encephalan-EEGR", "elite" suite. Display and record of EMG, ECG, EOG, RespEff etc., continuous measurement and record of electrode impedance and potentials, control of photo- and phonostimulation, topographic mapping, split mode. Quantitative analysis methods: coherent function, autocorrelation function, automatic artifact suppression, synchronization of data from additional wireless devices, record of data and analysis results on a disk for viewing and consultation, print manager for studies results;
    • Patient data management "Cardfile"
Attention! Electrode set "Encephalan-ES" should be included into delivery set of electroencephalograph according to the customer’s order (item 2-4), also recommended to purchase ECG cable (item 56) for disposable ECG electrodes (item 61).
  OR  
  À_6014 Basic set of Electroencephalograph-Recorder "Encephalan-EEGR-19/26" Modification "Mini" (telemetric and autonomous EEG studies, option of autonomous data accumulation on the integrated memory card (2GB)) version AT-Mini and also for PSG, Video, Poly versions supply.
    Basic set for À_6014 includes:
    • Patient transceiver-recorder (ABP -10): 9 EEG, 1 ECG, integrated ABP position sensor, ABP-10 can be used as a recorder with 10 custom polygraphical channels (also for PSG with 6 or 2 EEG channels); integrated telemetric interface (Bluetooth®) of connection to PC and additional wireless devices; autonomous data recording on the internal memory card (2GB);
    • Rechargeable batteries set – 2 pcs., charger, calibrator, cover bag, operation documentation;
    • Wireless PC Adapter IB-4 (USB–Bluetooth);
    • Software for autonomous-telemetric EEG studies, "Encephalan-EEGR" - "elite" suite, with additional functions of long-term registration and data recording on a memory card, their analysis and processing;
    • Patient data management "Cardfile"
Attention! Electrode set "Encephalan-ES" should be included into delivery set of electroencephalograph according to the customer’s order (item 2-4), also recommended to purchase ECG cable (item 56) for disposable ECG electrodes (item 61).
1.1. À_6429 Basic set of Additional Electroencephalograph-Recorder "Encephalan-EEGR-19/26" modification “Mini” (up to 10 additional units for main Electroencephalograph (item 1), as to main station) for long-term autonomous EEG, EEG-PSG and other studies of Holter type monitoring.
    Basic set for A_6429 includes:
    • Patient transceiver-recorder (ABP-10): 9 EEG, 1 ECG, integrated ABP position sensor, there is on option of using ABP-10 in the mode of 10 polygraphic channels with selective set of recorded parameters, which includes PSG studies (6 or 2 EEG-channels); integrated telemetric interface (Bluetooth®) of connection to PC and additional wireless devices; option of autonomous data accumulation on the integrated memory card (2GB);
    • Rechargeable batteries set – 2 pcs., charger, calibrator, cover bag, operation documentation;
    Attention!
    • Electrode set "Encephalan-ES" should be included into delivery set of electroencephalograph according to the customer’s order (item 2-4), also recommended to purchase ECG cable (56) for disposable ECG electrodes (61).
    • The delivery set of additional electroencephalograph-recorder does not contain wireless PC adapter IB-4 (USB–Bluetooth) and software suit. The work of additional recorders in telemetric mode with wireless PC adapter IB-4 and software suite of the main electroencephalograph (item 1) is guaranteed. At the basic station (PC of the main electroencephalograph) data analysis is performed and results are saved in the "Cardfile" database.
    • For the work of additional autonomous recorder in the mode of PSG-stuides or multiparametric monitoring, the corresponding software suite should be installed at the basic station, and the additional recorder should be supplied with required wireless devices and sensors.
2.   EEG Electrode Set ES-EEG-10/20 "Encephalan-ES" (customer selectable) for EEG studies - 9 EEG, 1 ECG
2.1. À_2493-41 Set Of Electrodes and Accessories "baby" (electrode system ES-EEG-8-3B, caps with eyelet holes, 5 sizes of elastic fixing caps and covers for them, sizes from 34 to 45, brushes for electrode cleaning, disposable ECG electrodes - 50 pcs., electrode gel – 1 bottle)
2.2. À_2493-42 Set of Electrodes and Accessories "children" (electrode system ES-EEG-8-3C, caps with eyelet holes, 5 sizes of elastic fixing caps and covers for them, sizes from 45 to 55, brushes for electrode cleaning, disposable ECG electrodes - 50 pcs., electrode gel – 1 bottle)
2.3. À_2493-43 Set of Electrodes and Accessories "adult" (electrode system ES-EEG-8-3A, caps with eyelet holes, 5 sizes of elastic fixing caps and covers for them, sizes from 55 to 66, brushes for electrode cleaning, disposable ECG electrodes - 50 pcs., electrode gel – 1 bottle)
3.   EEG Electrode Set ES-EEG-10/20 "Encephalan-ES" (customer selectable, Set “Baby” on request) for multiparametric indices monitoring or EEG and PSG studies - 2 EEG, 1 ECG, 1 EMG, 4 poly. To supply AT-Somno version (2 EEG), are required: additional set of sensors and accessories for wireless respiration module for 4 polygraphic channels of Poly-10 (item 34.1.), or wireless pulseoximeter (item 35.), it is possible to supply devices for restless legs syndrome diagnostics, item 32 or 37, to control body position – item 33., and for cardiorespiratory monitoring (item 36 or 37) and software suite "Encephalan-PSG" (item 20.). Can be supplied by sensors (item 39-64) (customer selectable).
3.1. À_2493-62 Set of Electrodes and Accessories "children" (electrode system ES-EEG-4-3C, caps with eyelet holes, 5 sizes of elastic fixing caps and covers for them, sizes from 45 to 55, brushes for electrode cleaning, disposable ECG electrodes - 50 pcs., electrode gel – 1 bottle)
3.1.1. À_2493-65 Set of Electrodes and Accessories "children" (electrode system ES-EEG-4-3C, with cup electrodes, 5 sizes of elastic fixing caps and covers for them, sizes from 45 to 55, brushes for electrode cleaning, disposable ECG electrodes - 50 pcs., electrode gel – 1 bottle)
3.2. À_2493-63 Set of Electrodes and Accessories "adult" (electrode system ES-EEG-4-3A, caps with eyelet holes, 5 sizes of elastic fixing caps and covers for them, sizes from 55 to 66, brushes for electrode cleaning, disposable ECG electrodes - 50 pcs., electrode gel – 1 bottle)
3.2.1. À_2493-66 Set of Electrodes and Accessories "adult" (electrode system ES-EEG-4-3A, with cup electrodes, 5 sizes of elastic fixing caps and covers for them, sizes from 55 to 66, brushes for electrode cleaning, disposable ECG electrodes - 50 pcs., electrode gel – 1 bottle)
4.   EEG Electrode set ES-EEG-10/20 "Encephalan-ES" (customer selectable, Set “Baby” on request) for EEG and PSG studies - 6 EEG, 1 ECG, 2 EOG, 1 EMG.
To supply AT-Somno version (6 EEG), are required: additional set of sensors and accessories for wireless respiration module (item 34.1.) for 4 polygraphic channels of Poly-4 (item 37), or wireless respiration module (item 34), Wireless Pulseoximeter (item 35), it is possible to supply devices for restless legs syndrome diagnostics, item 32 or 37, to control body position – item 33., and for cardiorespiratory monitoring item 36 or 37 and software suite "Encephalan-PSG" (item 20.)
4.1. À_2493-52 Set of Electrodes and Accessories "baby" (electrode system ES-EEG-6-3B, 5 sizes of elastic fixing caps and covers for them, sizes from 45 to 55, brushes for electrode cleaning, disposable ECG electrodes - 50 pcs., electrode gel – 1 bottle)
4.1.1. À_2493-55 Set of Electrodes and Accessories "children" (electrode system ES-EEG-6-3C, with cup electrodes, 5 sizes of elastic fixing caps and covers for them, sizes from 45 to 55, brushes for electrode cleaning, disposable ECG electrodes - 50 pcs., Electrode Cream EC-2 for EEG cup electrodes – 1 tube).
4.2. À_2493-53 Set of Electrodes and Accessories "adult" (electrode system ES-EEG-6-3A, 5 sizes of elastic fixing caps and covers for them, sizes from 55 to 66, brushes for electrode cleaning, disposable ECG electrodes - 50 pcs., electrode gel – 1 bottle)
4.2.1. À_2493-56 Set of Electrodes and Accessories "adult" (electrode system ES-EEG-4-3A(c), with cup electrodes, 5 sizes of elastic fixing caps and covers for them, sizes from 55 to 66, disposable ECG electrodes - 50 pcs., Electrode Cream EC-2 for EEG cup electrodes – 1 tube)
5. À_4062 Connector EEG-9 for connecting to patient transceiver-recorder (ABP-10) up to 13 electrodes with touchproof connectors (including cup, depth or cortical EEG electrodes and 1 derivation for ECG electrode).
6. A_5452 Defibrillation Proof Connector to connect to ABP-10 in ICU and reanimation up to 13 electrodes with touchproof connector (including cup, depth or cortical EEG electrodes and 1 derivation for ECG electrode)
7. A_6045 Electrode Set for Connector EEG-9 (item 5) with touchproof connectors for routine EEG studies: cup EEG electrodes set KEEG-8/21-00 – 14 electrodes and 4 ear clips (bracket (bridge) EEG electrodes on demand), EEG caps (silicon tubes) of 3 sizes, universal cable (2 pcs.) for ECG; disposable ECG electrodes (50 pcs.), electrode gel (1 bottle).
7.1. A_1854 Electrode Gel (1 bottle) for EEG electrodes
7.2. À_2229 ECG Electrodes Set (clips – 3 pcs.)
8. A_5332 Set of Cup EEG Electrodes for connectors from items 5 and 6 with touchproof connectors for long term EEG recording – 15 electrodes, ECG cables with buttons – 2 pcs.; disposable ECG electrodes (50 pcs.), cream EC-2 for disc electrodes – 1 tube
8.1. À_6532 Electrode Cream EC-2 (100g tube) for EEG cup (disc) electrodes
8.2. A_2669 Ten20 Conductive Paste (jar) for EEG cup (disc) electrodes
9.   Set of Disposable Electrodes for EEG registration, with cable and TouchProof type connector (start set 100 pcs.)
10. À_6679 Set of electrode extension leads (7 pcs. In a set; length 19,69 inches; for disposable electrodes with short cable)
11. A_5447 Mains Supply Adapter for APB-10
12. A_5360 USB Power Supply Adapter for APB-10
13. A_5528 Table Mount for ABP-10
14. A_2800 Floor Stand for ABP-10
15. A_2624 Stimulator SFN/FO-04 (autonomous photic stimulator) with integrated LED matrix – for photic stimulation tests during EEG studies in telemetric mode and for audio and electro stimulation in connection with headphones and wireless electro stimulator.
15.1. A_3149 Calibrated Headphones for audio stimulation
15.2. A_2940 LED Tube FO-06 TD (children) (can be fixed with elastic cap and electrode system)
15.3. A_3072 LED Tube FO-06 TV (adults) (can be fixed with elastic cap and electrode system)
15.4. A_4008 Wireless Electrostimulator (addition to item 15) for somatosensory stimulation while performing EP-studies (item 27) and stimulation for patient’s responses testing in reanimation and ICU.
15.5. À_6430 Floor Stand for wireless photic stimulator
15.6. À_5894 Table Mount for photic stimulator
16. A_1715 Voice Event Marker DCM-32M for recording voice comments (study log) and marking events during autonomous EEG study with following synchronization of recorded audio data with EEG recording
17. A_2329 SW-key (USB dongle) for software usage on additional PC including network variant
18. A_2143 Additional 2GB Memory Card (for items 1 and 1.1)

Equipment, software suite and accessories for synchronized videomonitoring version AT-Video

Software for additional study types expanding functional capabilities of electro encephalograph and software for versions of AT-PSG with required accessories and additional devices

Additional devices which extend the number of channels, sets of sensors and accessories for electroencephalograph according to the selected version and additional study types

Additional adapters, electrodes, sensors and accessories with "Micro-8" plug connection for ABP-10 polygraphic channels, wireless modules RM, PG-ECG, POLY-4, ABP-10 (using POLY-10)

Required computing hardware and office equipment

Additional licensed software

Service