Electroencephalographs-recorders computerized portable "Encephalan-EEGR-19/26" (main modification)
|
 |
Electroencephalographs-recorders computerized portable "Encephalan-EEGR-19/26" ("Mini" modification)
|
 |
|
Cerebral Function Monitor "Encephalan-CFM"
|
 |
|
Psychophysiological telemetric system "Rehacor-T"
|
 |
|
Electroencephalograph-analyzer EEGA-21/26 "Encephalan-131-03"
|
 |
|
Neuromyoanalyzer "Neuromyan"
|
 |
|
 |
Neuromyoanalyser NMA-4-01 "Neuromyan"
European Quality Certificate CE 538571, issued by British Standards Institute (BSI) valid till 02/09/2013
Neuromyoanalyser NMA-4-01 "Neuromyan" comes in two, four and five-channel modifications for electromyog-raphic studies and for studies of evoked potentials (EP). Different combination of hard- and software with neuromyoanalyzer’s modifications ensure different variants of functional capabilities of the device. Analyzer can be used for functional diagnostics, diagnostic centers, neurosurgical clinics, sport medicine and ex-perimental laboratories of scientific-research institutes.
Pattern stimulator, neuromyograph remote control, footswitch and neuromyograph patient block are wirelessly connected which significantly reduces the number of connectional cables at the working place of neurophysi-ologist and increases comfort for doctor and patient during the study process.
This data is of informative character. To form the specific set of equipment for delivery address the commercial department.
Illustrated product list
Delivery set is formed according to the table below by agreement with the
customer.
| Item # |
Ref. no. |
Description |
| 1. |
|
Modifications of neuromyoanalyser: |
| 1.1. |
A_2987-0 |
Modification 01 - 2 channel Variant "Basic".
A set includes Basic kit* of equipment and accessories, and also EMG/EP studies software, "Basic" variant for muscle & peripheral nerves diseases diagnostics, including following techniques:
Motor Nerve Conduction (MCV); Sensory Nerve Conduction (SCV); F-wave; Surface EMG; Neuromuscular transmis-sion by means of rhythmic stimulation – Decrement test; Brainstem Auditory Evoked Potentials (BAEP); Long Latency Auditory Evoked Potentials (LAEP); Flash Visual Evoked Potentials (FVEP); Somatosensory evoked potentials (SSEP). |
| 1.2. |
A_2987-1 |
Modification 01 - 2 channel Variant "Professional".
A set includes Basic kit* of equipment and accessories, and also EMG/EP studies software " Professional" variant, including following techniques additional to "Basic" variant:
Motor Unit Potential (MUP); Н-reflex; Blink-reflex; Single surface EMG; Middle Latency Auditory Evoked Potentials (MAEP); Long Latency Somatosensory Evoked Potentials (LSEP) |
| 1.3. |
A_2988-0 |
Modification 02 - 4 channel Variant "Basic".
A set includes Basic kit* of equipment and accessories, and also EMG/EP studies software, "Basic" variant, includ-ing techniques of multi-channel studies of symmetric muscle and them antagonists as an additional to modification 01 - "Basic" variant. |
| 1.4. |
A_2988-1 |
Modification 02 - 4 channel Variant " Professional
A set includes Basic kit* of equipment and accessories, and also EMG/EP studies software " Professional" variant, including techniques of multi-channel studies of symmetric muscle and them antagonists as an additional to modification 01 - "Professional" variant.
A set also includes following additionals:
Wireless foot-operated switch (3 pedals) for stimulation control; Wireless remote control (functional keyboard). |
| 1.5. |
A_2941 |
Modification 03 - 5 channel Variant " Professional".
A set includes Basic kit* of equipment and accessories, and also EMG/EP studies software " Professional" variant, (methodic set as in the item.1.4.) for fine differential diagnostics of central and peripheral nervous system disorders, de-tailed study of the muscles disorders and testing of neuromuscular transmission using five channels. Five-channel record of EP for detection by-chiasmatic and the central visual dysfunction is provided. Option of recording EMG via two channels and EP via three channels allows to reduce to a minimum necessity of electrodes change at performance of EP, EMG tests.
A set also includes following additionals:
Wireless foot-operated switch (3 pedals) for stimulation control; Wireless remote control (functional keyboard). |
* Basic set, included in each modification:
- Patient block, including: various quantity of high-quality channels of EMG and EP record, integrated interface of connection to Wireless func-tional keyboard, Wireless foot-operated switch and a visual CPR stimulator, integrated photic- phonic and electrostimulation, and also USB in-terface to communication with PC;
- Mains Supply Adapter;
- Table Mount for patient block;
- Headphones for auditory EP;
- Photostimulator – goggles for flash visual EP;
- Electrodes and accessories kit in as consisted with SW.
|
| Item # |
Ref. no. |
Description |
| 2. |
A_3066 |
Methodic of visual EP study on a reversed chess pattern – including wireless chess pattern stimulator – an additional LCD monitor is required. |
| 3. |
A_3006 |
Basic set of electrodes and accessories for needle myographic studies (Disposable needles 0.46*37 mm (50 pcs).; Disposable needles 0.46*50 mm (25 pcs).; cable for needle electrodes, 2 m, 5-DIN - 1 pcs). Set composition can be changed at Customer's option. |
| 4. |
A_3069 |
Wireless foot-operated switch (3 pedals) for stimulation control (for items 1.1., 1.2 and 1.3) |
| 5. |
A_3061 |
Wireless remote control (functional keyboard) (for items 1.1, 1.2 nad 1.3) (The keyboard settles down in one hand, work with it is comparable with habitual management of a mobile phone, is in addition used as the handle of electrostimulation with the built in regulator). |
| 6. |
A_3378 |
Magnetic stimulator for diagnostic and therapeutic stimulation of cerebral cortex motor zones and peripheral nervous system |
| 7. |
|
Audiometric headphones (TDH-39) for auditory EP
|
| Item # |
Ref. no. |
Description |
| 8. |
|
Real Time Work Station with Installed Medicom-MTD Software Suite (Portable Computer) selected by customer. Minimal requirements: Intel Core i3 370M, 2.3GHz, 3M; RAM 4GB, HDD 320GB, monitor 15.6", DVD-RW, discrete graphic card, OS Windows 7, mouse |
| 9. |
|
Real Time Work Station with installed Medicom-MTD Software Suite (Stationary Computer) selected by customer. Minimal requirements: Intel Ci3 210x, 2GB RAM, HDD 500+ GB, DVD-RW, discrete video adapter with DVI, OS Windows 7, mouse, keyboard, monitor 21,5” - 1pcs., UPS |
| 10. |
A_0687 |
Additional LCD Monitor 21,5" |
| 11. |
A_4087 |
Laser Black-And-White Printer A4 format |
| 12. |
A_4300 |
Active 2.1 Acoustic system |
| 13. |
A_3155 |
Equipment trolley |
| Item # |
Description |
| 14. |
Acronis® Backup & Recovery – recommended for installation to provide quick recovering of operation system and installed software in case of SW work faults |
| 15. |
Antivirus application "Kaspersky Internet Security 2012" – recommended for installation to provide security from viruses during the net work or work with external drives. |
| 16. |
MS Office (minimal package – Word and Excel) – for install on a PC at Customer's option |
| Item # |
Description |
| 17. |
Product delivery to the customer |
| 18. |
Training (5 days of practical work with equipment under experts supervision) in MANUFACTURER's technical center (Ta-ganrog, Russia). Travel expenses are not included. |
| 19. |
Start-up and commissioning (at customer's site) |
| 20. |
1-year warranty period at customer's site |
| 21. |
2-year warranty period at the manufacturer's service center (Taganrog, Russia) |
|