Electroencephalographs-recorders computerized portable "Encephalan-EEGR-19/26" (main modification)
|
 |
Electroencephalographs-recorders computerized portable "Encephalan-EEGR-19/26" ("Mini" modification)
|
 |
|
Cerebral Function Monitor "Encephalan-CFM"
|
 |
|
Psychophysiological telemetric system "Rehacor-T"
|
 |
|
Electroencephalograph-analyzer EEGA-21/26 "Encephalan-131-03"
|
 |
|
Neuromyoanalyzer "Neuromyan"
|
 |
|
 |
Psychophysiological telemetric system "Rehacor-T" Illustrated product list
| Ref. no. |
Component |
Use |
| A_5321 |
Patient Multifunction Transceiver "ABP-4" |
 |
Is meant for physiological signals recording, their amplification, preprocessing, transforming into digital code and transmission of this code into PC via wireless channel ("Bluetooth"-technology). |
| A_2894 |
Battery Charger |
 |
Is meant for charging the rechargeable batteries. |
| A_0294 |
Wireless PC Àdapter IB-4 |
 |
Connected to PC via USB. Ensures connection of all wireless devices
with PC via Bluetooth. |
| A_4731 |
Simulator |
 |
Is connected to the "ABP-4" and intended to calibrate EEG channels. |
| A_3817 |
Cable for Disposable N Electrode |
 |
With TouchProof connector for Poly-6 and EEG-20 |
| A_5228 |
USB Power Supply Adapter |
 |
Adapter can be inserted into battery compartment instead of batteries. Adapter is designed for "Poly-4" power supply from PC USB port. |
| A_5346 |
Mains Supply Adapter |
 |
Adapter can be inserted into battery compartment instead of
batteries. Adapter is designed for "Poly-4" mains supply. |
| A_4626 |
ABP-BFB electrodes, sensors and accessories kit – for biofeedback training with "Rehacor" software |
 |
Includes sensors and cables of GSR, skin conductance, PPG – 1 pcs; respiration effort, temperature, EEMG – 2 pcs; ECG cable – 1 pcs.; universal electrode cable for EEG and EMG derivations – 2 pcs., tubular EEG electrodes – 2 pcs; ECG, EMG, EOG disposable electrodes (50 pcs.), electrode gel (1 tube) |
| A_6541 |
Caps Set "Children", 5 sizes from 45 to 55 |
 |
Elastic EEG caps CS-EEG-FBC-C |
| A_6542 |
Caps Set "Adult", 5 sizes from 55 to 66 |
Elastic EEG caps CS-EEG-FBC-A |
| À_2229 |
Set of ECG electrodes (3 clips) |
 |
For ECG recording |
| A_4008 |
Wireless Electrostimulator |
 |
Designed for somatosensory stimulation. Control over stimulator is
performed from stimulator SFN/FO-04 via Bluetooth. |
| A_6473 |
Stabiloanalyzer (balance platform) |
 |
For additional diagnostics and BFB training by stabylogram (adapter required) |
| A_4813 |
Wireless I/O Adapter |
 |
For stabyloanalyzer |
| Ref. no. |
Component |
Use |
| A_2329 |
SW-key |
 |
Allows running software on additional PC for analyzing and viewing
recorded studies data. |
| À_2493-72 |
Set of electrodes and accessories "children" (electrode system ES-EEG-4-1C, sizes from 45 to 55) |
 |
Caps with eyelet holes, 5 sizes of elastic fixing caps and covers for them, brushes for electrode cleaning, electrode gel – 1 bottle) |
| A_2493-73 |
Set of electrodes and accessories "adult" (electrode system ES-EEG-4K-1A, sizes from 55 to 66) |
| A_2493-75 |
Set of electrodes and accessories "children" (electrode system ES-EEG-4K-1C(c), sizes from 45 to 55) |
With cup electrodes, 5 sizes of elastic fixing caps and covers for them, Electrode cream EC-2 for cup electrodes – 1 bottle) |
| A_2493-76 |
Set of electrodes and accessories "adult" (electrode system ES-EEG-4K-1A(c), sizes from 55 to 66) |
| A_1854 |
Electrode Gel |
 |
For EEG, ECG and EMG |
| A_6532 |
Electrode Cream EC-2 (tube) |
 |
For EEG cup electrodes |
| Ref. no. |
Component |
Use |
| — |
EEG-Videomonitoring Kit |
Designed for EEG videomonitoring, includes video cameras, microphone, and means to input videosignal into PC. |
| A_2310-31 |
Mobile Basic (Day) |
 |
One professional daylight video camera – optical Zoom, rotator, quality MPEG4, patient’s microphone, portable stand for camera |
| A_2310-32 |
Mobile Basic (Day-Night) |
 |
One professional day-night video camera – digital Zoom, rotator, quality MPEG4, IR backlight for night mode, patient’s microphone, portable stand for camera |
| A_2310-33 |
Mobile Basic Advanced (Day-Night) |
 |
One professional day-night video camera – optical Zoom, rotator, quality MPEG4, IR backlight for night mode, patient’s microphone, portable stand for camera |
| A_2651 |
Events Marker (IR, wireless) |
 |
Allows setting event marks in the studies record directly from patient’s ward. |
| Ref. no. |
Component |
Use |
| A_2732 |
Wireless Movement Sensor |
|
Module cooperates with ABP-5 with the help of Bluetooth and designed for recording patient’s extremities motor activity. |
| A_4163 |
Wireless Pulseoximeter Module |
 |
Module cooperates with ABP with the help of Bluetooth and designed for record of oxygen degree in blood. |
| A_4085-05 |
Fingertip SpO2 Sensor R-3227 (soft small) |
 |
— |
| A_4085-03 |
Fingertip SpO2 Sensor R-3227 (soft medium) |
 |
— |
| A_4085-04 |
Fingertip SpO2 Sensor R-3227 (soft large) |
 |
— |
| A_4085-06 |
Neonatal Disposable Spo2 Sensor DN-2311-6 (set of 24 pcs.) for neonatal use |
 |
— |
| A_4404 |
Wireless Respiration Module |
|
Registers 4 channels of respiratory sensors synchronously with EEG. Used for respiration disorders detection during PSG studies |
| A_5365 |
Set of Sensors and Accessories for Wireless Respiration Module |
|
Respiration effort sensors, thoracal and abdominal, snore sensor, oral and oral-nasal thermistor airflow sensors, nasal cannula (disposable cannulas should be purchased individually.
The set can be used with POLY-4 module or ABP-10 to record signals via 10 polygraphic channels (POLY-10)
|
| A_2442 |
Wireless Cardiorespiratory Module |
 |
Module cooperates with ABP with the help of Bluetooth and adds to the system 4 channels for 1 channel respiration parameters record and ECG via 3 derivations. |
| A_4768 |
PG-ECG Connector |
 |
Connected to the Wireless Cardiorespiratory Module. Is designed for connection of cables from the PG-ECG Cable Kit. |
| A_5359 |
POLY-4 Wireless Module
|  |
Module cooperates with ABP with the help of Bluetooth and adds to the system 4 polygraphic channels. |
| A_5364 |
ABP-POLY Electrodes, Sensors and Accessories set |
 |
For monitoring the movement activity in natural behavior and also for Study of Limbs Movements During Sleep. Includes movement sensors (wired) – 2 pcs., cables for 2 EMG derivations), disposable electrodes are required.
The set can be used with Poly-4 module (item 35) or ABP-10 (item 36) in the POLY-10 mode.
|
| A_5228 |
USB Power Supply Adapter |
 |
Adapter can be inserted into battery compartment instead of batteries. Adapter is designed for "Poly-4" power supply from PC USB port. |
| A_5346 |
Mains Supply Adapter |
 |
Adapter can be inserted into battery compartment instead of
batteries. Adapter is designed for "Poly-4" mains supply. |
| Ref. no. |
Component |
Use |
| A_4772 |
Tetrapolar Rheographic Adapter (RT) |
 |
For evaluation of central hemodynamics rheography and heart pumping ability parameters |
| A_5338 |
Accessories and electrodes set for rheographic adapter RT |
 |
For carrying out of rheographic studies, using RT Rheographic Adapter |
| A_4771 |
Bipolar rheographic adapter (RB) for REG and RVG |
 |
For evaluation of cerebral (REG) and peripheral (RVG) blood circulation, which characterizes pulse blood filling, variable diameter vessels tone and venous drainage state |
| A_5339 |
Accessories and electrodes set for rheographic adapter RB |
 |
For carrying out of rheographic studies, using RB Rheographic Adapter |
| A_2673 |
Respiratory Effort Sensor |
 |
Sensor with respiratory belt to record thoracic and abdominal respiration.
(All electrodes and sensors designed for connection to ABP, RR module, Wireless cardiorespiratory module (PG-ECG), Wireless Module "Poly-4", are supplied with 8-pin connectors.)
|
| A_4406 |
Pressure Airflow Sensor |
 |
Designed for respiration airflow evaluation by means of air pressure registering. |
| A_4007-03 |
Disposable Nasal Cannula (neonatal) |
| A_4007-02 |
Disposable Nasal Cannula (children) |
| A_4007-01 |
Disposable Nasal Cannula (adult) |
| A_5697 |
Oral Airflow Sensor (Thermistor "T-Flow") |
 |
Evaluates parameters of oral respiration (breathing rate and amplitude, duration of in-and exhalation phases) and detects breathing disorders basing on temperature changes of oral airflow. |
| A_2326 |
Oro-Nasal Airflow Sensor (Thermistor "T-Flow") |
 |
Evaluates parameters of nasal respiration (breathing rate and amplitude, duration of in-and exhalation phases) and detects breathing disorders basing on temperature changes of oro-nasal airflow. |
| A_1869 |
Snore Sensor ("Snore") |
 |
Detects and evaluates snoring during sleep quantitatively |
| A_4140 |
Ear PPG Sensor |
 |
Record of the pulse curve to calculate peripheral circulation. |
| A_4141 |
Surface PPG Sensor |
 |
Record of the pulse curve to calculate peripheral circulation. |
| A_4139 |
Temperature Sensor |
 |
Designed for temperature record. |
| A_4142 |
Envelope EMG Sensor (double) |
 |
Record of muscle tone via envelope EMG. |
| A_5731 |
Envelope EMG Sensor (triple) |
 |
Record of muscle tone via envelope EMG. |
| A_4143 |
GSR Sensor |
 |
Galvanic skin response record (relative impedance change). |
| A_5119 |
Skin Conductance Sensor (EDA-ElectroDermal Activity) |
 |
Evaluates vegetative manifestations and emotional stress basing on phase and tonic component measurement |
| A_5118 |
Light sensor |
 |
For evaluation of light conditions in a room during the somnological studying. |
| A_5117 |
Wet Sensor |
 |
Designed for detecting wet caused by urination. |
| A_5361 |
Movement Sensor |
 |
Designed for recording patient’s extremities motor activity. |
| A_2073 |
ECG Cable for Disposable Electrodes |
 |
Designed for connecting the ECG electrodes. |
| A_3817 |
Cable for Disposable N Electrode |
 |
With TouchProof connector for Poly-6 and EEG-20 |
| A_4194 |
Bipolar EÌG Cable |
 |
With 2 snap connector for disposable electrodes. |
| A_2741 |
Disposable ECG electrode F26 PG-10S |
 |
N-electrode universal. |
| A_5825 |
Adhesive Plaster |
 |
For electrodes, sensors and conductors fixation. |
| Ref. no. |
Component |
| — |
Real Time Work Station with Installed Medicom-MTD Software Suite (Portable Computer) |
 |
| — |
Real Time Work Station with Installed Medicom-MTD Software Suite (Stationary Computer) with Additional LCD Monitor 22", Laser Black-And-White Printer A4 format and Equipment Trolley |
 |
| A_4742 |
Bluetooth-GPS module |
 |
For tracking patient's location |
|