Electroencephalographs-recorders computerized portable "Encephalan-EEGR-19/26" (main modification)
|
 |
Electroencephalographs-recorders computerized portable "Encephalan-EEGR-19/26" ("Mini" modification)
|
 |
|
Cerebral Function Monitor "Encephalan-CFM"
|
 |
|
Psychophysiological telemetric system "Rehacor-T"
|
 |
|
Electroencephalograph-analyzer EEGA-21/26 "Encephalan-131-03"
|
 |
|
Neuromyoanalyzer "Neuromyan"
|
 |
|
 |
Psychophysiological telemetric system "Rehacor-T"
European Quality Certificate CE 538571, issued by British Standards Institute (BSI) valid till 02/09/2013 Registration Certificate of Federal Supervision Service for Healthcare and Social Development
#FSR 2010/07253 issued from 08.09.2009
Psychophysiological telemetric system "Rehacor-T" provides realization of self-regulation skills, rehabilitation procedures basing on biological feedback (biofeedback training) in order to improve patient’s resistance to stress factors using "Rehacor" software suit. The system can be used for non-medicated restoration of impaired functions, improving nerve regulation for different diseases, phobias, pathologies and addictions (both in children and adults), and for forming required psychophysiological status in sportsmen and men of stressed professions. Includes an option of multiparametric control of VNS and CNS parameters during biofeedback training, telemetric and autonomous data monitoring in the training process, e.g. for sportsmen training. Multifunctional biofeedback procedures library uses wide multimedia capabilities of modern PCs for most types of biofeedback and neurofeedback training and allows modifying and adapting required procedures or creating new ones considering esthetic, intellectual, age and other patient peculiarities.
"Rehacor-T" device can be supplied with "HRV" software for evaluation of vegetative nerve system state basing on the heart rate variability analysis and "Encephalan-PSG" software for polysomnographic studies (apnea screening and sleep structure disorders).
"Reahcor-T" offers multichannel recording (from 5 to 16 channels) of different physiological parameters and signals in required combinations: electroencephalographic (EEG), respiration effort and airflow, electrocardiographic (ECG), electromyographic (EMG), envelope electromyogram (EEMG), photoplethysmographic (PPG), skin potential response (SPR), galvanic skin response (GSR), oxygen saturation (SpO2), skin conductance (EDA – Electrodermal Activity), temperature (Ò), impedance plethysmographic, stabylogram and others. Registering is carried out with 5-channel patient transceiver-recorder (100g weight) and additional wireless devices with possible extension of the simultaneously recorded parameters number to 16.
This data is of informative character. To form the specific set of equipment for delivery address the commercial department.
Illustrated product list
Delivery set is formed according to the table below by agreement with the customer:
| Item # |
Ref. no. |
Description |
| 1.1 |
À_6038 |
Basic set including:
- Patient Transceiver-Recorder (ABP-4): 4 universal polygraphic channels, internal position sensor, integrated telemetric interface (Bluetooth®) for connection to PC (USB) and additional wireless devices, data recording on the internal memory card (if there is software suit according to the item 3);
- Rechargeable batteries set – 2 pcs., charger (power supply adapters item 1.1.1 or item 1.1.2 can be purchased on customer’s request);
- Wireless PC Adapter IB-4 (USB–Bluetooth), calibrator, N-electrode cable;
- Patient data management "Cadfile"; operation documentation;
Attention! "Rehacor-T" delivery set should include: software suit "Rehacor" (item 1.2), sensors set (item 1.2.1), customer selectable additional procedures, software suits, equipment and accessories (item 1.2.2 – 1.2.5) which extents functional capabilities of "Rehacor-T" (items 3 – 5), additional units, modules, electrodes, sensors and accessories (items 6 – 35), computers, office equipment and software (items 36 – 47) |
| 1.1.1. |
À_5346 |
Mains Supply Adapter for ABP-4
|
| 1.1.2. |
À_5228 |
USB Power Supply Adapter for ABP-4
|
| 1.1.3. |
À_5362 |
Table Support for ABP-4 |
| 1.2. |
A_1010 |
"Rehacor" Software Suit for Functional Biocontrol with Biofeedback Training
Software provides procedures of functional biocontrol with biofeedback training using different physiological parameters – EEG, HRV, GSR, EMG, respiration, temperature, PPG, REG, Rheo-CHD and others in different combinations. Stress testing with audio-visual and somatosensory stimuli and patient responce analysis allow optimizing biofeedback training process. Course dynamics analysis software allows visualization of tendencies (graphically or in the table form) of controlled parameters changing at all training sessions. Expandable library and scenario editor help in creation of new methodic or editing existing ones.
Attention!
- To work with software, you should purchase electrodes, sensors and accessories from the set ABP-FBC (item 1.2.1).
- To enable an option of biofeedback training by blood circulation parameters, additionally purchase rheoadapters, (items 11 and 12).
|
| 1.2.1. |
À_4626 |
BFB Accessories Kit – electrodes, sensors and accessories for biofeedback training with "Rehacor" software.
Includes sensors of GSR, skin conductance, PPG (1 pcs.); respiration effort, temperature, EEMG (2 pcs); ECG cable; universal electrode cables (2 pcs.) for EMG or SP derivations, cables and sensors for 2 bipolar EEG, disposable electrodes for ECG, EMG and EOG (50 pcs), electrode gel – 1 bottle.
Attention! Caps for EEG electrodes fixation (items 1.2.1.1 and 1.2.1.2) should be purchased additionally on customer’s select.
Customer can select additional sensors from items 11 – 35.
|
| 1.2.1.1. |
A_6541 |
Caps set (elastic EEG caps) "children" CS-EEG-4C, 5 sizes from 45 to 55 |
| 1.2.1.2. |
A_6542 |
Caps set (elastic EEG caps) "adult" CS-EEG-4A, 5 sizes from 55 to 66 |
| 1.2.1.3. |
A_2229 |
Set of ECG electrodes (3 clips) |
| 1.2.2. |
A_4008-99 |
Wireless electrostimulator with stress resistance improvement methodic |
| 1.2.3. |
A_1010-10 |
Procedure of Combined Operator's Activity (Addition to "Rehacor" Software for Functional Biocontrol with Biofeedback Training) (item 1.2) Software provides the combination of following the moving objects on screen with logical tasks solving. Parameters of activity model are adaptively changing according to the efficiency of procedure performing, which allows evaluating the functional capabilities of a test person. |
| 1.2.4. |
A_6473* |
Stabiloanalyzer (balance platform)for additional diagnostics and biofeedback training by stabylogram (adapter required – item 1.2.4.1.) |
| 1.2.4.1. |
A_4813* |
Wireless I/O adapter (for stabyloanalyzer)
|
| 1.2.5. |
A_1786* |
Acoustic Sensory Chair with 16 integrated acoustic channels and 16-Channel Audio Amplifier |
| 1.2.5.1. |
A_3224* |
16-Channel Audio Amplifier with software for 16 acoustic channels environmental control |
| 1.2.5.2. |
|
A Set of Acoustic Systems (16 pcs.) to be placed in psychological release room (can be purchased by a customer individually)
|
| Item # |
Ref. no. |
Description |
| 2. |
À_2329 |
SW-key (USB dongle) allows an additional installation and working with purchased software and researching data on a client’s PC, including network variant |
| 3. |
A_1627-01 |
"Encephalan-PSG" software for somnological studies, "Basic" suite (for apnea screening and sleep structure disorders) Telemetric and autonomous monitoring of physiological parameters for sleep stages analysis, automatic building and manual editing of hypnograms, marking sleep events, reporting for sleep stages statistics, sleep stages distribution, respiration and movement’s disorders etc. There can be only an option of apnea screening. Data on physiological signals recorded with polygraphic channels and wireless devices in the monitoring process, is also analyzed.
Attention!
- To work only in apnea screening variant, you should purchase wireless pulse oximeter (item 7). And respiratory module sensors and accessories (item 8.1).
- To analyze the disorders of phase sleep structure and breathing disorders, in addition to respiratory module set and pulse oximeter, you should purchase the Poly-4 module (item 10), and electrode set "Encephalan-ES" in sets selected by customer (item 3.1).
- For telemetric or autonomous multiparametric monitoring of parameters and their analysis during patient’s free behavior (sleep, passive wakefulness, active wakefulness), the device should be additionally supplied with PG-ECG module (item 9) and Poly-4 module (item 10) with sensors selected by customer (items 11-35).
- If required, any configurarion can be supplied with movement sensors (item 6).
|
| 3.1 |
|
EEG electrode set ES-EEG-10/20 "Encephalan-ES" (customer selectable, set “Baby” on request) - 2 bipolar derivation of EEG and 2 EOG |
| 3.1.1. |
À_2493-72 |
Set of electrodes and accessories "children" (electrode system ES-EEG-4-1C, caps with eyelet holes, 5 sizes of elastic fixing caps and covers for them, sizes from 45 to 55, brushes for electrode cleaning, electrode gel – 1 bottle) |
| 3.1.2 |
À_2493-75 |
Set of electrodes and accessories "children" (electrode system ES-EEG-4K-1C(c), with cup electrodes, 5 sizes of elastic fixing caps and covers for them, sizes from 45 to 55, Electrode cream EC-2 for cup electrodes – 1 bottle) |
| 3.1.3 |
À_2493-73 |
Set of electrodes and accessories "adult" (electrode system ES-EEG-4K-1A, caps with eyelet holes, 5 sizes of elastic fixing caps and covers for them, sizes from 55 to 66, brushes for electrode cleaning, electrode gel – 1 bottle) |
| 3.1.4 |
À_2493-76 |
Set of electrodes and accessories "adult" (electrode system ES-EEG-4K-1A(c), with cup electrodes, 5 sizes of elastic fixing caps and covers for them, sizes from 55 to 66, Electrode cream EC-2 for cup electrodes – 1 bottle) |
| 3.2 |
A_1854 |
Electrode gel (bottle) for EEG electrodes |
| 3.3 |
A_6532 |
Electrode cream EC-2 (100g tube) for EEG cup electrodes |
| 4. |
|
EEG-Videomonitoring kit,
includes accessories and software suite for synchronized EEG and video data recording, analysis and storage. Includes option of short video clip preparation for demonstration of a significant alterations, with further recording of this data onto optical discs or memory cards with specialized "EEG Viewer" application (provides main functions of visual EEG analysis) for analysis of specified EEG fragments with video data at the PC of the consulting doctors.
Video monitoring kit variants is to be selected by a customer and supplies additionally to software item 3:
|
| 4.1. |
A_2310-31 |
Mobile basic (day):
one professional daylight video camera – optical Zoom, rotator, patient’s microphone, patients events IR receiver (for item 4.4.1), portable stand for camera, wall mount |
| 4.2. |
A_2310-32 |
Mobile basic (day-night):
one video camera with night mode – digital Zoom, rotator, IR backlight for night mode, patient’s microphone, patients events IR receiver (for item 4.4.1), portable stand for camera, wall mount |
| 4.3. |
A_2310-33 |
Mobile basic advanced (day-night):
one professional video camera with night mode – optical Zoom, rotator, IR backlight for night mode, patient’s microphone, patients events IR receiver (for item 4.4.1), portable stand for camera, wall mount |
| 4.4. |
|
Optional: |
| 4.4.1. |
A_2651 |
Events marker (IR, wireless) for any kit from item 4. |
| 5. |
A_1964 |
"HRV" software for heart rate variability analysis
Evaluation of VNS state and neurohumoral patient reaction on the basis of HRV study connected with provoking actions. Software is used to evaluate the adequacy of physical and physical-emotional stress, to control the behavior of medicinal drugs and efficiency of treatment prescribed. Software uses standard recommended types of quantitative analysis and results representation in the form of cardiointervalogram trends (RR) of statistical and spectral parameters, hystograms and scattergrams (correlation rhythmograms) of RR-intervals allocation, spectrograms with frequency ranges that characterize the state of VNS and balance of sympathetic parasympathetic sections (HF, LF, VLF). There is an option of forming the formalized protocol with initial state description and vegetative reactivity. Software allows analyzing selected fragments of continuous (day or night) ECG records during long-term EEG, PSG studies or multiparametric monitoring. |
| Item # |
Ref. no. |
Description |
| 6. |
A_2732 |
Wireless Movement Sensor (for movement activity) registers legs movement data to detect the restless legs syndrome (at lest 2 sensors required) or other body parts movements depending on the place of fixation mainly for PSG studies multiparametric (telemetric or autonomous) monitoring in sport medicine, scientific research, etc. |
| 7. |
A_4163 |
Wireless pulse oximeter module, with fingertip sensor provides synchronous with EEG recording of patient arterial blood oxygen saturation. Can be supplied with additional sensors (items 7.1 – 7.4), and other types, on request. Used mainly for PSG studies (item 3).
|
| 7.1. |
A_4085-05 |
Fingertip SpO2 sensor RS-3227 (soft small) |
| 7.2. |
A_4085-03 |
Fingertip SpO2 sensor RM-3227 (soft medium) |
| 7.3. |
A_4085-04 |
Fingertip SpO2 sensor R-3227 (soft large) |
| 7.4. |
|
SpO2 sensors of other types, including disposable |
| 8. |
A_4404 |
Wireless respiration module registers of 4 channels of respiratory sensors (item 8.1) synchronously with EEG. Used for respiration disorders detection during PSG studies. |
| 8.1. |
A_5365 |
Set of sensors and accessories for wireless respiration module
(respiration effort sensors, thoracal and abdominal, snore sensor, oral and oral-nasal thermistor airflow sensors, nasal cannula (disposable cannulas should be purchased individually) (items 14.1 – 14.3).
The set can be used with POLY-4 module (items 10).
|
| 9. |
A_2442 |
Wireless Cardiorespiratory Module
(PG-ECG) registers of 3 polygraphic channels from ABP-4 and rheopneumogram synchronously with EEG for visual analysis of cardiorespiratory disorders in the process of PSG studies or for multiparametric (telemetric or autonomous) monitoring in sport medicine, scientific research. The delivery set should be supplied with electrodes, sensors and accessories (item 9.1). |
| 9.1. |
A_4768 |
PG-ECG connector with ECG cables (for children and adults). Disposable EEG electrodes are not included into the delivery set (7 pcs. required for a study).
PG-ECG connector can be used with POLY-4 module. |
| 10. |
A_5359 |
POLY-4 wireless module registers of 4 polygraphic channels from ABP-4. If used for PSG studies to diagnose the restless legs syndrome, should be supplied with electrodes and sensors (item 10.1). Can be supplied with sensors according to the items 8.1, 10.1 for additional cardiorespiratory monitoring or optional (items 11 – 35) according to customer’s request for multiparametric (telemetric or autonomous) monitoring in sport medicine, scientific research, etc. |
| 10.1. |
A_5364 |
Electrodes, Sensors and Accessories set for monitoring the movement activity in natural behavior and also for Study of Limbs Movements During Sleep (movement sensors (wired) – 2 pcs., cables for 2 EMG derivations), disposable electrodes are required (item 33).
|
| 10.2. |
A_5228 |
USB power supply adapter for POLY-4 module |
| 10.3. |
A_5346 |
Mains power supply adapter for POLY-4 module |
| Item # |
Ref. no. |
Description |
| 11. |
A_4772* |
Tetrapolar Rheographic Adapter (RT) for evaluation of central hemodynamics rheography and heart pumping ability parameters. |
| 11.1. |
A_5338* |
Accessories and electrodes set for rheographic adapter RT |
| 12. |
A_4771* |
Bipolar Rheographic Adapter (RB) for REG and RVG
For evaluation of cerebral (REG) and peripheral (RVG) blood circulation, which characterizes pulse blood filling, variable diameter vessels tone and venous drainage state.
|
| 12.1. |
A_5339* |
Accessories and electrodes set for rheographic adapter RB |
| 13. |
A_2673 |
Respiratory Effort Sensor ("RespEf") evaluates parameters of abdominal and thoracic respiration (breathing rate and amplitude, duration of in-and exhalation phases) and detects breathing disorders basing on respiration belt stretching measurement |
| 14. |
A_4406 |
Pressure Airflow Sensor ("P-Flow") evaluates parameters of nasal respiration (breathing rate and amplitude, duration of in-and exhalation phases) and detects breathing disorders basing on pressure gradient |
| 14.1. |
A_4007-03 |
Nasal Cannula (neonatal) |
| 14.2. |
A_4007-02 |
Nasal Cannula (children) |
| 14.3. |
A_4007-01 |
Nasal Cannula (adult) |
| 15. |
A_5697 |
Oral Airflow Sensor (Thermistor "T-Flow") evaluates parameters of nasal respiration (breathing rate and amplitude, duration of in-and exhalation phases) and detects breathing disorders basing on temperature changes of oral airflow. |
| 16. |
A_2326 |
Oro-Nasal Airflow Sensor (Thermistor "T-Flow") evaluates parameters of nasal respiration (breathing rate and amplitude, duration of in-and exhalation phases) and detects breathing disorders basing on temperature changes of oro-nasal airflow. |
| 17. |
A_1869 |
Snore Sensor ("Snore") detects and evaluates snoring during sleep quantitatively |
| 18. |
A_4140 |
Photoplethysmogram (PPG) Sensor for ear ("PPG") evaluates parameters of peripheral blood circulation which characterize pulse blood filling and different vessels tone |
| 19. |
A_4141 |
Photoplethysmogram (PPG) surface Sensor ("PPG") evaluates parameters of peripheral blood circulation which characterize pulse blood filling and different vessels tone |
| 20. |
A_4139 |
Temperature sensor evaluates skin surface temperature in selected body area |
| 21. |
A_4142 |
Envelope EMG Sensor EEMG-2 evaluates tone of selected muscle basing on envelope EMG measurement |
| 22. |
A_5731 |
Envelope EMG sensor EEMG-3 evaluates tone of selected muscle basing on envelope EMG measurement |
| 23. |
A_4143 |
GSR Sensor ("GSR") to evaluate vegetative manifestations and emotional stress basing on phase component measurement |
| 24. |
A_5119 |
Skin Conductance Sensor (EDA-ElectroDermal Activity) evaluates vegetative manifestations and emotional stress basing on phase and tonic component measurement |
| 25. |
A_5118 |
Light Sensor ("Light") evaluates illumination during the PSG study |
| 26. |
A_5117 |
Wet Sensor ("Wet") for bedwetting detection during the PSG study |
| 27. |
A_5361 |
Movement sensor (wired) |
| 28. |
A_2073 |
ECG cable for disposable electrodes (2 electrodes) |
| 29. |
A_3817 |
N Electrode Lead (snap connector wire with touch ðroof connector) |
| 30. |
A_4194 |
Bipolar EÌG Cable (with 2 snap connector for disposable electrodes) for EMG or skin potential response (SPR) channel
|
| 31. |
A_5202 |
Bipolar EEG Cable (with 2 electrodes for EEG caps with eyelet holes) |
| 32. |
A_4031 |
Bipolar EEG Cable (with 2 cup electrodes) |
| 32.1. |
A_6532 |
Electrode cream EC-2 (100g tube) for EEG cup electrodes |
| 33. |
A_2714 |
Disposable ECG electrode (for EOG, EMG) – 50 pcs in 1 pack |
| 34. |
A_1854 |
Electrode gel 250 ml |
| 35. |
|
Adhesive plaster for electrodes, sensors and conductors fixation |
| Item # |
Description |
| 36. |
Real Time Work Station with Installed Medicom-MTD Software Suite (Portable Computer)
selected by customer. Minimal requirements: Intel Core i3 370M, 2.3GHz, 3M; RAM 4GB, HDD 320GB, monitor 15.6", DVD-RW, discrete graphic card, OS Windows 7, mouse |
| 37. |
Real Time Work Station with installed Medicom-MTD Software Suite (Stationary Computer) selected by customer. Minimal requirements: Intel Ci3 210x, RAM 2GB, HDD 500+GB, DVD-RW, discrete video adapter with DVI, OS Windows 7, mouse, keyboard, monitor 22", UPS |
| 38. |
Mobile HDD 500 GB |
| 39. |
Widescreen LED TV set |
| 40. |
Additional LCD monitor 22" |
| 41. |
Laser black-and-white printer A4 format |
| 42. |
Active 2.1 acoustic system |
| 43. |
Bluetooth-GPS module (for tracking patient's location (for item 1)) |
| 44. |
Equipment trolley for PC and monitor |
| Item # |
Description |
| 45. |
Acronis® Backup & Recovery – recommended for installation to provide quick recovering of operation system and installed software in case of SW work faults
|
| 46. |
Antivirus application "Kaspersky Internet Security 2012" – recommended for installation to provide security from viruses during the net work or work with external drives |
| 47. |
MS Office RUS (minimal package – Word and Excel) necessary to install in the case of SW cl.6 purchasing
|
| 48. |
Product delivery to the customer |
| 49. |
Training (5 days of practical work with equipment under experts
supervision) in MANUFACTURER’s technical center (Taganrog, Russia).
Travel expenses are not included. |
| 50. |
Installation and commissioning (at customer’s site) |
| 51. |
1-year warranty period at customer’s site |
| 52. |
2-year warranty period at the manufacturer’s service center
(Taganrog, Russia) |
|